{"id":20,"date":"2016-12-09T14:09:40","date_gmt":"2016-12-09T13:09:40","guid":{"rendered":"http:\/\/emmegi-gmbh.de\/?page_id=20"},"modified":"2024-08-20T13:41:17","modified_gmt":"2024-08-20T11:41:17","slug":"luft-oel-kuehler","status":"publish","type":"page","link":"https:\/\/emmegi-gmbh.de\/en\/produkte\/luft-oel-kuehler\/","title":{"rendered":"Oil-Air coolers"},"content":{"rendered":"<h1>Oil-Air coolers<\/h1>\n<div class=\"su-row\">\n<div class=\"su-column su-column-size-1-2\"><div class=\"su-column-inner su-u-clearfix su-u-trim\">\n<img decoding=\"async\" class=\"alignnone size-full wp-image-217 breit\" src=\"http:\/\/emmegi-gmbh.de\/wp-content\/uploads\/2016\/12\/produkte_luft_oel_kuehler_2.jpg\" alt=\"Oil-Air coolers Series MG 2000 K + HPA\" width=\"500\" height=\"\" srcset=\"https:\/\/emmegi-gmbh.de\/wp-content\/uploads\/2016\/12\/produkte_luft_oel_kuehler_2.jpg 500w, https:\/\/emmegi-gmbh.de\/wp-content\/uploads\/2016\/12\/produkte_luft_oel_kuehler_2-300x210.jpg 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p>\n<\/div><\/div>\n<div class=\"su-column su-column-size-1-2\"><div class=\"su-column-inner su-u-clearfix su-u-trim\">\n<h2>Series MG 2000 K + HPA<\/h2>\n<p>Oil-Air coolers are primarily used in return flow circuits of hydraulic systems with fan drive in order to cool down the utilized oil.<\/p>\n<p>The core block made out of high-strength aluminum is manufactured by using a production system which includes a well-engineered welding procedure. In order to increase the turbulent flow of the liquid and consequently the heat removal a special configuration of the direction of flow is applied. Additional elements of turbulence also support the increased efficiency of EMMEGI heat exchangers. Those components result in a compact, rugged, technically mature and up-to-date product.<\/p>\n<\/div><\/div>\n<\/div>\n<hr class=\"grau\" \/>\n<div class=\"su-row\">\n<div class=\"su-column su-column-size-1-2\"><div class=\"su-column-inner su-u-clearfix su-u-trim\">\n<h4>Serie MG AIR<\/h4>\n<div class=\"su-list\" style=\"margin-left:0px\">\n<ul>\n<li><i class=\"sui sui-angle-double-right\" style=\"color:#333\"><\/i> spec. cooling power: 0,03 &#8211; 1,3 Kw \/ \u00b0C<\/li>\n<li><i class=\"sui sui-angle-double-right\" style=\"color:#333\"><\/i> oil flow rate: 2 &#8211; 320 Ltr \/ min<\/li>\n<\/ul>\n<\/div>\n<dl>\n<dt>2000 K:<\/dt>\n<dd>Air \/ Oil Heat Exchanger<\/dd>\n<dt>KBV:<\/dt>\n<dd>Air \/ Oil Heat Exchanger 2000K incl. integrated by-pass valve<\/dd>\n<\/dl>\n<hr class=\"grau\" \/>\n<h4>Serie HPA<\/h4>\n<div class=\"su-list\" style=\"margin-left:0px\">\n<ul>\n<li><i class=\"sui sui-angle-double-right\" style=\"color:#333\"><\/i> spec. cooling power: 0,2 &#8211; 6,5 Kw \/ \u00b0C<\/li>\n<li><i class=\"sui sui-angle-double-right\" style=\"color:#333\"><\/i> oil flow rate: 20 &#8211; 650 Ltr \/ min<\/li>\n<\/ul>\n<\/div>\n<dl>\n<dt>HPA<\/dt>\n<dd>Air \/ Oil Heat Exchanger up to 5 Kw \/ \u00b0C<\/dd>\n<dt>HPA Large<\/dt>\n<dd>Air \/ Oil Heat Exchanger up to 6,5 Kw \/ \u00b0C<\/dd>\n<dt>HPA Compact<\/dt>\n<dd>Air \/ Oil Heat Exchanger HPA as compact version<\/dd>\n<dt>HPV<\/dt>\n<dd>Air \/ Oil Heat Exchanger HPA incl. integrated by-pass valve<\/dd>\n<dt>HPA TK<\/dt>\n<dd>Air \/ Oil Heat Exchanger with tank<\/dd>\n<dt>HPA ATEX<\/dt>\n<dd><\/dd>\n<dt>HPA Marine<\/dt>\n<dd><\/dd>\n<\/dl>\n<\/div><\/div>\n<div class=\"su-column su-column-size-1-2\"><div class=\"su-column-inner su-u-clearfix su-u-trim\">\n<h3>Technical Data \/ Specifications<\/h3>\n<div class=\"su-table su-table-alternate\">\n<table>\n<tbody>\n<tr>\n<td>Material<\/td>\n<td>highly resistant &amp; persistent aluminum alloy<\/td>\n<\/tr>\n<tr>\n<td>Operating pressure<\/td>\n<td>20 bar<\/td>\n<\/tr>\n<tr>\n<td>AC-Fan Drive<\/td>\n<td>230V, 50 Hz<\/td>\n<\/tr>\n<tr>\n<td>3 Phase-Fan Drive<\/td>\n<td>230\/400 V, 50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td>DC-Fan Drive<\/td>\n<td>12V und 24 V DC<\/td>\n<\/tr>\n<tr>\n<td>Oil Flow<\/td>\n<td>2 &#8211; 500 Ltr \/ min<\/td>\n<\/tr>\n<tr>\n<td>Spec. Cooling Power<\/td>\n<td>bis zu 5 kW \/ \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div><\/div>\n<\/div>\n<hr class=\"grau\" \/>\n<div class=\"su-row\">\n<div class=\"su-column su-column-size-1-2\"><div class=\"su-column-inner su-u-clearfix su-u-trim\">\n<h3>Field of applications<\/h3>\n<p>industrial hydraulic, hydraulic aggregates, hydraulic machines, hydraulik presses<br \/>\nmobile hydraulic : construction machinery, off road machinery, mining + drilling machines, cranes<br \/>\n<\/div><\/div>\n<div class=\"su-column su-column-size-1-2\"><div class=\"su-column-inner su-u-clearfix su-u-trim\">\n<h3>Downloads<\/h3>\n<div class=\"su-row\">\n<div class=\"su-column su-column-size-1-2\"><a class=\"link\" href=\"http:\/\/emmegi-gmbh.de\/wp-content\/uploads\/2024\/04\/Air-Oil-Exchangers-2000K-series.pdf\" target=\"_blank\" rel=\"noopener\"><i class=\"fa fa-file-pdf-o fa-pdficon \" ><\/i> Air-Oil Exchangers &#8211; 2000K series<\/a><a class=\"link\" href=\"http:\/\/emmegi-gmbh.de\/wp-content\/uploads\/2024\/04\/Air-Oil-Exchangers-MOBILE-series.pdf\" target=\"_blank\" rel=\"noopener\"><i class=\"fa fa-file-pdf-o fa-pdficon \" ><\/i> Air-Oil Exchangers &#8211; MOBILE series<\/a><\/p>\n<p><a class=\"link\" href=\"http:\/\/emmegi-gmbh.de\/wp-content\/uploads\/2024\/04\/Air-Oil-Exchangers-DRAIN-series.pdf\" target=\"_blank\" rel=\"noopener\"><i class=\"fa fa-file-pdf-o fa-pdficon \" ><\/i> Air-Oil Exchangers &#8211; DRAIN series<\/a><\/p>\n<p><a class=\"link\" href=\"http:\/\/emmegi-gmbh.de\/wp-content\/uploads\/2024\/04\/Air-Oil-Exchangers-EBR-series.pdf\" target=\"_blank\" rel=\"noopener\"><i class=\"fa fa-file-pdf-o fa-pdficon \" ><\/i> Air-Oil Exchangers &#8211; EBR series <\/a><\/p>\n<p><a class=\"link\" href=\"http:\/\/emmegi-gmbh.de\/wp-content\/uploads\/2024\/04\/Air-Oil-Exchangers-KBV-series-with-incorporated-by-pass.pdf\" target=\"_blank\" rel=\"noopener\"><i class=\"fa fa-file-pdf-o fa-pdficon \" ><\/i> Air-Oil Exchangers &#8211; KBV series with incorporated by-pass <\/a><\/p>\n<p><a class=\"link\" href=\"http:\/\/emmegi-gmbh.de\/wp-content\/uploads\/2024\/04\/Air-Oil-Exchangers-HPA-series.pdf\" target=\"_blank\" rel=\"noopener\"><i class=\"fa fa-file-pdf-o fa-pdficon \" ><\/i> Air-Oil Exchangers &#8211; HPA series <\/a><\/p>\n<\/div>\n<div class=\"su-column su-column-size-1-2\">\n<p><a class=\"link\" href=\"http:\/\/emmegi-gmbh.de\/wp-content\/uploads\/2024\/04\/Air-Oil-Exchangers-HPA-LARGER-series.pdf\" target=\"_blank\" rel=\"noopener\"><i class=\"fa fa-file-pdf-o fa-pdficon \" ><\/i> Air-Oil Exchangers &#8211; HPA LARGER series <\/a><\/p>\n<p><a class=\"link\" href=\"http:\/\/emmegi-gmbh.de\/wp-content\/uploads\/2024\/04\/Air-Oil-Exchangers-HPA-COMPACT-series.pdf\" target=\"_blank\" rel=\"noopener\"><i class=\"fa fa-file-pdf-o fa-pdficon \" ><\/i> Air-Oil Exchangers &#8211; HPA COMPACT series <\/a><\/p>\n<p><a class=\"link\" href=\"http:\/\/emmegi-gmbh.de\/wp-content\/uploads\/2024\/04\/Air-Oil-Exchangers-HPA-TK-series.pdf\" target=\"_blank\" rel=\"noopener\"><i class=\"fa fa-file-pdf-o fa-pdficon \" ><\/i> Air-Oil Exchangers &#8211; HPA TK series <\/a><\/p>\n<p><a class=\"link\" href=\"http:\/\/emmegi-gmbh.de\/wp-content\/uploads\/2024\/04\/Air-Oil-Exchangers-HPV-series-with-incorporated-By-Pass.pdf\" target=\"_blank\" rel=\"noopener\"><i class=\"fa fa-file-pdf-o fa-pdficon \" ><\/i> Air-Oil Exchangers &#8211; HPV series with incorporated By-Pass <\/a><\/p>\n<p><a class=\"link\" href=\"http:\/\/emmegi-gmbh.de\/wp-content\/uploads\/2024\/04\/ATEX-certified-heat-exchangers-HP\u0404x-series.pdf\" target=\"_blank\" rel=\"noopener\"><i class=\"fa fa-file-pdf-o fa-pdficon \" ><\/i> ATEX certified heat exchangers &#8211; HP\u0404x series <\/a><\/p>\n<\/div>\n<\/div>\n<\/div><\/div>\n<\/div>\n<a href=\"https:\/\/emmegi-gmbh.de\/en\/kontakt\/\" class=\"su-button su-button-style-default\" style=\"color:#ffffff;background-color:#239bd2;border-color:#1c7ca8;border-radius:5px\" target=\"_self\"><span style=\"color:#ffffff;padding:0px 18px;font-size:14px;line-height:28px;border-color:#65b9e0;border-radius:5px;text-shadow:none\"> Contact us<\/span><\/a>","protected":false},"excerpt":{"rendered":"<p>Oil-Air coolers<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":114,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-20","page","type-page","status-publish","hentry"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/emmegi-gmbh.de\/en\/wp-json\/wp\/v2\/pages\/20","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/emmegi-gmbh.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/emmegi-gmbh.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/emmegi-gmbh.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/emmegi-gmbh.de\/en\/wp-json\/wp\/v2\/comments?post=20"}],"version-history":[{"count":41,"href":"https:\/\/emmegi-gmbh.de\/en\/wp-json\/wp\/v2\/pages\/20\/revisions"}],"predecessor-version":[{"id":1449,"href":"https:\/\/emmegi-gmbh.de\/en\/wp-json\/wp\/v2\/pages\/20\/revisions\/1449"}],"up":[{"embeddable":true,"href":"https:\/\/emmegi-gmbh.de\/en\/wp-json\/wp\/v2\/pages\/114"}],"wp:attachment":[{"href":"https:\/\/emmegi-gmbh.de\/en\/wp-json\/wp\/v2\/media?parent=20"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}